Drawing Soaps

Choosing a drawing soap for high carbon wire drawing

Spring, rope, bead, hose and PC wire raise drawing force, die temperature and total reduction. A drawing soap that runs well on low carbon nail and binding wire may not hold up here. This article looks at wire drawing lubricant selection by carbon level.

The same drawing soap that runs without trouble on low carbon nail wire can turn into a burnt, blackened deposit a few dies down a high carbon spring wire line. That is not because the soap is “bad” but because the two materials create completely different conditions inside the die. As carbon content rises, yield strength, drawing force and frictional heat all rise together, and the soap has to survive those conditions as a film.

This article looks at soap choice by carbon level: what high carbon wire (roughly 0.5–0.9 % C; patented spring, rope, bead/hose and PC wire) demands from a wire drawing lubricant, how that differs from low carbon wire, and how the soap can be staged along the line. For the basics of reactive versus neutral soap see drawing soap selection and die life; for surface preparation and patenting of these products see PC strand and spring steel wire.

Why is high carbon wire harder on the soap?

  • Higher drawing force: pearlitic high carbon wire is stronger and work-hardens further with every pass. Contact pressure at the die entry rises, and the film has to stay intact under higher pressure.
  • More heat: deformation work and friction turn into heat. At the same reduction and speed, high carbon wire leaves the die noticeably hotter than low carbon wire, and the die zone temperature approaches the soap's softening range.
  • A longer reduction path: going from rod to finished size takes more dies and a higher total reduction. The film built at the first die has to be carried through to the last.
  • Low tolerance for defects: on spring, rope and PC wire, surface scoring and lubrication-related overheating can show up in fatigue and torsion behaviour.

With high carbon wire, heat is not only a die life issue. If wire temperature is not brought down enough between passes, drawn high carbon wire can show strain ageing: ductility drops, and torsion tests may show irregular fractures and delamination. Where exactly that limit lies depends on the steel, the size and the line layout, but every lubrication break that raises friction pushes the wire a little closer to it.

What low and high carbon wire need from the soap

CriterionLow carbon wire (≈0.05–0.25 % C)High carbon wire (≈0.5–0.9 % C)
Typical productsNail, mesh, binding wire, wire for galvanizing, welding wireSpring, rope, bead, hose and PC wire
Drawing force and pressureModerateHigh; increases along the line with work hardening
Die zone temperatureSpeed-dependent, generally lowerHigh; heat resistance is decisive
Priority for the soapEven film, low dusting, clean surfaceHeat resistance, film strength, continuity
Carrier layerOften lime/borax, or bare surface after mechanical descaling; phosphate depends on productUsually zinc phosphate; coating weight set by total reduction
Grain structureFine, free-flowing; even pick-up at high speedFilm-carrying in early dies, finer grain in the finishing dies
Residue sensitivityHigh before galvanizing and weldingProduct-dependent before heat treatment, plating and rope lubrication
Typical riskDusting, build-up at die entry, dull finishFilm breakdown, burnt soap, excessive wire temperature, breaks
Drawing soap requirements in low vs high carbon wire drawing

Which soap properties matter for high carbon?

The first test of a soap in high carbon drawing is temperature. The soap should soften at the die entry and be dragged into the die as a viscous film; if it melts too early the film thins and the die runs dry, if it does not soften at all too little film reaches the die. High carbon lines therefore favour formulations with a higher softening range and good thermal stability. In practice these are often sodium-rich soaps or sodium-calcium blends with a higher softening range; pure calcium stearate melts at a lower temperature than sodium stearate (details: calcium vs sodium drawing soap). The base metal alone does not decide it: both families come in different heat classes, and the right class is chosen according to line speed and cooling.

  • Softening / melting range: must match the die zone temperature. The range given in the product TDS should be read together with soap box and die temperatures on the line.
  • Film strength: must hold without tearing under high pressure. The bonded layer formed by a reactive soap with the phosphate is an advantage on heavy passes.
  • Continuity and carry-through: the film must not run out over many dies; this is as much the job of the carrier layer as of the soap.
  • Grain size and flow: the soap should wrap the wire evenly in the box without tunnelling; coarse grain builds up in the finishing dies.
  • Resistance to burning: soap that blackens and hardens on overheating and forms a crust in the die cone damages both surface and die.
  • Residue: if heat treatment, plating or galvanizing follows, how the remaining soap will be removed should be planned from the start.

Critical soap properties by wire type

What each wire type needs from the drawing soap (general tendency; varies by line)
Wire typeHeat resistanceFilm strengthContinuity over the reductionFine grain, even finishLow, removable residue
Nail and binding wire (low C)Light to moderate reduction; heat resistance comes in at high speed, dusting and finish come firstRelevantCritical
Mesh and construction wire (low C)High-speed multi-die lines; heat and film carry-through matter togetherCriticalRelevantRelevant
Wire for galvanizing and welding (low C)The next line is sensitive to surface cleanliness; residue is decisiveRelevantCritical
Spring wire (high C)High pressure and heat; residue also matters for heat treatment and coating after drawingCriticalCriticalCriticalRelevant
Rope wire (high C)Long reduction sequence and fine finished size; an even film is needed in the finishing diesCriticalRelevantCriticalRelevantRelevant
PC wire (high C)Heavy sizes and heavy passes; film strength and heat resistance come firstCriticalCriticalCritical
Bead and hose wire (high C)Metallic coating after drawing; heat resistance and cleanability are weighed togetherCriticalRelevantRelevantCritical

CriticalRelevant

The marks in the matrix are not a recipe but a map of where to start the conversation. For example, if the same spring wire goes straight to coiling and stress relieving after drawing, residue may be secondary; if it goes to a coating line, residue comes to the front.

From first die to last: staging the soap

On multi-die dry drawing machines with a separate soap box in front of each die, different soaps can be used along the line. With high carbon wire this is particularly valuable, because the first dies and the last dies are dealing with different problems:

Staging the drawing soap on a multi-die high carbon line
  1. First box and early dies

    The phosphated surface picks up soap for the first time. Building the base film comes first: a soap with good adhesion and high film-carrying capacity, often a reactive one.

    • Base film
    • Film carry
  2. Intermediate dies

    The wire has work-hardened and heated up, and heat accumulates from pass to pass. A grade with a high softening range and strong heat resistance is decisive here.

    • Heat resistance
    • Capstan cooling
  3. Finishing dies

    The wire is at its highest strength and the surface finish is set here. A finer-grained soap that gives an even film, without giving up heat resistance.

    • Fine grain
    • Surface finish
  4. After drawingProduct-dependent

    Residue level is checked before heat treatment, plating or stranding; a cleaning step is planned where needed.

General approach; the number of stages and the soap types depend on the line layout

Running the whole line on one soap is also possible and simpler for stock management; the chosen grade is then sized for the heat of the intermediate dies, accepting some compromise on finish in the last dies. For how the film forms in the soap box and why tunnelling occurs, see dry drawing soap film stability.

Coating weight and soap are sized together

On high carbon wire even the most heat-resistant soap cannot go the distance if the carrier layer is insufficient. The zinc phosphate layer holds the soap in its pores and carries it into the die, while a reactive soap consumes part of that layer by reaction. On lines with high total reduction, coating weight is therefore planned towards the upper part of the 3–15 g/m² range in which KIMSOL operates, and the soap is chosen together with that value. If breaks concentrate after a particular die number, first check whether the layer is running out there; coating weight measurement explains how to measure it.

Why is the picture different on low carbon wire?

On low carbon products such as nail, mesh and binding wire the material is softer and drawing force and heat are lower, but speed and volume are high. Here the soap's real test is not heat but film uniformity: a coarse or heavily filled soap dusts, builds up at the die entry and spoils a bright finish. If the wire goes on to galvanizing or welding, keeping residue from burdening the next line matters as much as die life. Low carbon lines therefore favour finer, clean-running soaps, while heat resistance comes back into play on high-speed construction wire lines. More detail in drawing nail, mesh and binding wire.

Speed, cooling and soap: what sets the limit?

Raising speed on a high carbon line directly raises heat per die and wire temperature. The soap can absorb that increase up to a point; beyond it, die and capstan cooling decide. Blackened, hard soap crust in the die, lumping in the soap box and a drop in torsion results after a speed increase are typical signs that the limit has been reached. Moving to a soap in a higher heat class helps, but without reviewing cooling and reduction distribution it is not a lasting fix. This is also why the same line behaves differently in the hot season; see wire drawing in hot climates.

What information is needed for a soap recommendation?

  • Steel grade and carbon content; whether the rod is patented.
  • Rod and finished size, number of dies and pass schedule (reduction per die).
  • Line speed, machine type and die/capstan cooling arrangement.
  • Carrier layer: phosphate coating weight or the other carrier used.
  • Post-drawing processing: heat treatment, galvanizing, metallic coating, stranding.
  • Current problems: which die shows wear or breaks, torsion results, burnt soap, dusting.

With this information we can work out together which reactive or neutral grade from the Kimkal drawing soap range to use at which stage of your line; softening range and operating conditions are given in the product TDS. Get in touch with your line parameters.

Frequently asked questions

Why does high carbon wire drawing need a different drawing soap?

High carbon wire is stronger and work-hardens more during drawing, which means higher contact pressure and more heat in the die. It is also usually drawn through more dies with a higher total reduction. A soap that works on low carbon wire may soften too early under these conditions, the film thins, and die wear, burnt soap deposits or breaks can follow.

Which type of wire drawing lubricant is preferred for high carbon wire?

The general tendency is towards soaps with a higher softening range, good thermal stability and strong film strength under pressure; these are often sodium-rich formulations or sodium-calcium blends with a higher softening range. On phosphated wire, the bonded layer of a reactive soap is an advantage in the early dies. The exact grade depends on line speed, cooling, number of dies and post-drawing processing.

Can different soaps be used at different dies on the same line?

Yes. On multi-die machines with a separate soap box in front of each die, a common approach is a soap that builds the base film in the early dies, a heat-resistant grade in the intermediate dies and a finer-grained soap in the finishing dies. Running on a single soap is also possible; the grade is then chosen for the hottest intermediate dies.

Can excessive wire temperature damage high carbon wire?

It can. If wire temperature is not brought down enough between passes, strain ageing can reduce ductility, and torsion tests may show irregular fractures and delamination. The limit depends on the steel and size. Cooling is the first measure, but because a thinning soap film raises frictional heat, lubrication also directly affects wire temperature.

What should the soap deliver on low carbon nail and binding wire?

On low carbon wire drawing force and heat are lower while speed and volume are high. The soap is therefore expected first of all to give an even, thin film, low dusting and a clean surface. For products such as wire for galvanizing or welding wire, easy removal of residue is also decisive in the choice.

Related articles

Keep reading

Drawing Soaps

Drawing nail wire, mesh wire and binding wire: choosing the drawing soap

Nail wire, mesh wire, binding wire and galvanising feed wire come from the same low-carbon rod on similar machines, yet each asks something different of the surface. On fast multi-pass lines, matching the soap to the pass, the speed and the end use decides both die life and customer complaints.

8 min
Read →